Every year April 6h is 406 DAY ,celebrates the 406 Day to help raise awareness about safety devices called Personal Locator Beacons (PLBs) and Emergency Position Indicating Radio Beacons (EPIRBs).
Test Your 406 MHz Device at 406 Day
406 Day is the perfect day to test your 406MHz device(s).
- Self-Test: Most EPIRBs come equipped with a self-test function that allows you to verify the unit’s internal circuitry and battery status. Perform a self-test according to the manufacturer’s instructions.
- GPS Test (if applicable): If your EPIRB is equipped with GPS functionality, conduct a GPS test to ensure that the unit can accurately transmit your position to search and rescue authorities.
- Activation Test: If your EPIRB has a manual activation mechanism, physically activate the beacon to ensure that it deploys properly and transmits a distress signal.
- Signal Confirmation: After testing, confirm that the distress signal was successfully received by monitoring the appropriate channels or contacting your local maritime authority.
On ACR units like the ResQLink™, a “T” button activates the test. A coded LED/Strobe light flashes to let the owner know if the unit is functioning, has sufficient battery power, and that the GPS can acquire a satellite lock.
Mcmurdo
Smartfind G8 AIS Smartfind G8 Smartfind E8
Self-test & inspection
The EPIRB has a built-in self-test capability that can be used as a confidence check. This self-test confirms that the battery is healthy, that the GPS receiver and distress transmitters are
functional and that the strobe light is operational. The short self-test should be performed monthly and not more than 12 times per year. It should be performed during the first 5 minutes of the hour to minimise disturbance on the emergency channel.
Short self-test
1.Press the TEST button for 2 seconds and then release.
2.The green LED will flash once to confirm the short self-test has started.
NOTE – The green LED will also flash when the EPIRB makes a
transmission during normal operation or during a self-test.
3.The EPIRB performs internal checks.
4.The result of the self-test is indicated by the flashing of the white strobe
lights or the red LED according to the following table. The number of
times the strobe lights flash is an indication of the accumulated time the
battery has been in use.

Tron 60S EPIRB self-test
Self-test The purpose of a self-test is to verify that the EPIRB functions as it should. During this test, a short test signal on 121,5MHz and 406,037MHz are sent to test the output of the transmitter and operation of the EPIRB. While transmitting the test signal, the battery voltage and status, output power and phase lock are tested. When testing the 406MHz transmitter a test message is transmitted, this test message is coded with a special synchronization code that will not be recognized as an actual alert by the Cospas-Sarsat satellites. There are two types of tests: 1. Self-test 2. Extended self-test including GPS test
Testing should be completed within the first 5 mins of an hour as the satellite EPIRB emits a 121,5 MHz signal during testing.
To perform a self-test, do the following: 1. Remove the EPIRB from the bracket.
- Move the switch from the ready position to the test position and hold for 15 seconds.
Keep hands and/or other objects away from the antenna.
- Release the switch.
A single flash indicates a passed test. If this is not the result, refer to the error codes.
Error codes (flashes)
If the self-test detects an error in the EPIRB module, one or more of the following will occur: Number of Flashes:
Error codes
2 Low power on 406 MHz transmitter
3 Low battery voltage
4 Low power on 121.5 MHz transmitter
5 PLL on 406 MHz transmitter out of lock
6 PLL on 121.5 MHz transmitter out of lock
7 EPIRB module not programmed or programming not complete
self-testing a Kannad ELT 406.
Step 1: A 50 Ohms dummy load (or antenna) is connected to the BNC socket. Step 2: Switch from OFF to ARM Step 3: After about 10 seconds, 1 long flash (duration 1 second) shows that the self test is successful. If the self-test fails, the result will be 3 short flashes followed by 1 to 6 short flashes (refer to User Manual) Step 4 : Switch to OFF

SAMYUNG ENC SEP-406
Separate the beacon from the mounter
Carry the beacon to a tranquil place
Turn the Switch to the Test Position
The red LED indicator will be on for 5 seconds and the blink during 10 seconds
While testing , one burst for test is transmitted on 406.025MHZ and then the test signal is transmitted continuously on 121.5MHZ
To avoid transmitting actual distress signal on 121.5MHZ , it is not allowed that the test is continued over than 30 seconds.
NSR NEB-2000 Self Test
SELF TEST
It is recommended that the Self-Test should be taken every two months. To perform Self-Test, through the hole on the switch cover, use a tool to press and hold the TEST button for 3s, and then release the button. During Self-Test, the transmitting messages won’t be regarded as distress alert even received by satellite.
Check the LED status as below:
Step 1. All LED flickers once one by one.
Step 2. Strobe light flickers every 3 seconds during self-test.
Step 3. Sending a 121.5 MHz test homing signal to check the power and Frequency. – TX LED flashes short time once.
Step 4. Sending an AIS test message to check the power and frequency. – TX LED flashes short time twice.
Step 5. Sending a 406MHz test message to check the power and frequency. – TX LED flashes long time once.
Step 6. Finish the self-test.
SELF-TEST lasts for 30 seconds. The last 5 seconds is to indicate the test result.
– If passed, Status LED keep ON. –
– If failed, TX LED keep on. If PIE, LOW BAT LED keep on.
After 30 seconds, SELF-TEST ends and the EPIRB is powered off automatically.
NOTE : 1. GNSS receiver inside of the EPIRB is powered off when doing Self-Test. So GNSS LED status does not mean GNSS position locked or not at Self-Test. 2. During test, do not break the protection tab and do not open the switch cover. 3. PIE: Potentially Insufficient Battery Energy, the self-test number more than maximum 48.

VEP8 and VEP8A Self-test
Self-test mode Notice: Overuse selftest function can lead to untimely battery discharge. As 121.5 MHz signal is transmitted during self-test, this test may only be executed during the first five (5) minutes period of any hour.

- Take out the VEP8 from the release device;
- Carry the VEP8 to a open place;
- Push the switch to “TEST” position and hold it, refer to Fig 7;
- The STATE Indicator starts to blink and then stays on constantly after 10s. If strobe light blinks once, it means self-test is normal;
- If STATE flash after 10s, it means self-test is abnormal, and the associated fault indicator lights up;
- When testing, signal of 406MHz only transmits once, signal of 121.5MHz transmits 1s;
- After finishing self-test, let off of the switch, and it will automatically set to “AUTO” to turn off the VEP8.

In circumstances of self-test mode, the status of indicator refer to Table 3.