Suze Canal Searching light

The Suez Canal, located in Egypt, serves as a major international shipping route connecting Europe, Asia, and Africa. Currently, the Suez Canal is managed by the Suez Canal Authority (SCA). Vessels transiting the Suez Canal must comply with the Suez Canal Navigation Rules established by the Suez Canal Authority.

TZ5 suez pic1

The searchlight shall meet the following conditions and technical requirements:

It shall be positioned on the centerline of the bow, clearly illuminating the canal.

Its technical requirements are as follows:

(1) The minimum illumination distance for a single beam shall be 1800 meters ahead.

(2) The luminous intensity of the single beam provided by the lamp shall not be less than 3×IC (30,000 candelas), equivalent to the following power ratings for high-efficiency incandescent lamps:

 

For vessels of 2000 gross tons and below in the Suez Canal: 3000 W.

For vessels exceeding 3,000 gross tons in the Suez Canal, 30 watts shall be levied.

Alternatively, any lamp type meeting the technical requirements of (2) shall be explosion-proof.

(3) Bulbs and mountings shall be constructed of highly corrosion-resistant materials and capable of operating in both horizontal and vertical orientations.

(4) Front glass must be tempered and hardened.

(5) The reflector must consist of two precision ground glass halves of the highest quality, or a polished aluminum mirror, with a minimum reflectivity of 95% for glass mirrors.

(6) The two reflectors may be combined (at zero position) to form a single reflector beam, or divided horizontally into two independent beams, each inclined at least 5 degrees in the horizontal plane, with the dark zone between them adjustable within the range of 0° to 10°.

(7) The searchlight housing must be waterproof (test pressure 0.25 kg/m²). The electrical system (switches, plugs, sockets, and cables) must be Class 1 marine products with an IP55 protection rating.

(8) For enclosed searchlights installed on vessels carrying electrical equipment for hazardous areas (meeting classification society requirements), in addition to providing safe ventilation, the lamp housing shall include ventilation ports. A hose may be fitted to the drum to extract hot air from the lamp housing, facilitating the removal of internal heat. On vessels carrying petroleum products, liquefied natural gas, or flammable substances, or on vessels not degassed, hot air must be vented through non-flammable gas exhaust ports.

(9) Searchlights must have two lamp sockets to enable precise rotation of the bulb to the reflector’s focal point (maintaining the light beam accurately at the reflector’s focal point), and their current must be automatically switched on.

(10) Searchlights must possess a “Type Test” certificate. The type test must include illumination tests meeting the aforementioned technical requirements, with the certificate issued by a classification society. The original certificate shall be submitted to Suez Canal Authority (SCA) officials. The searchlight shall only be accepted after testing by an SCA inspector.

On all vessels described in Item 2(8) above, searchlight cables and all electrical connections must be permanently fixed, insulated, and gas-tight.

The cable end near the searchlight shall be fitted with a fixed, gas-tight explosion-proof socket.

On vessels employing electric propulsion or electric drives (e.g., steering gears, winches, etc.), the number of generators and the output power of each generator must be sufficient to ensure intermittent operation of the searchlight should one generator cease functioning. All vessels are exempt from this rule unless they carry separate generators and searchlight circuits.

If electrical connections and/or searchlights do not meet specifications, vessels may only transit the canal during daylight hours, causing delays. For third and subsequent transits, additional fees will apply if searchlights and/or electrical connections remain non-compliant.