Medium Precision MODBUS Dual Axis Inclination Sensor QJ726T-M
QJ726T-M is a medium-precision MODBUS dual-axis inclination sensor with built-in
high-precision inclination unit, which compensates and corrects the collected gravitational field change value through unique n-order filtering fusion
algorithm, and finally outputs the angle value.
Industrial grade design, communication interface RS232/RS422/RS485/TTL
default is MODBUSRTU (485). Measurement accuracy is 0.01°, resolution 0.001°.
Medium Precision MODBUS Dual Axis Inclination Sensor
Model : QJ726T-M

Introduction:
QJ726T-M is a medium-precision MODBUS dual-axis inclination sensor with built-in
high-precision inclination unit, which compensates and corrects the collected gravitational field change value through unique n-order filtering fusion
algorithm, and finally outputs the angle value.
Industrial grade design, working temperature range -40~+85℃; default communication interface
is MODBUSRTU (485). Measurement accuracy is 0.01°, resolution 0.001°.
Other special requirements can be customized
Accurate measurement and stable performance; unique anti-electromagnetic interference circuitry designed for industrial applications
ensures that the product can work stably for a long time in harsh industrial environments.
The product is easy to use, compact design, reserved for a variety of interfaces, suitable for integration into the system;
has been widely used in a variety of fields such as security monitoring and early warning, automation and leveling.
Application :
Tower poles, wind power generation equipment
Bridge health monitoring
Head leveling, aerial work trucks
Slopes and other geological disaster areas
Drilling rigs, offshore platforms
Dangerous houses, ancient buildings
High-supporting molds, Pit monitoring
Medical equipment
Angle control of various construction machinery
High-precision laser platforms

This protocol adheres to the MODBUS communication protocol, using a subset of the MODBUS protocol in the RTU mode. RS485 half-duplex work
mode of operation.
RS485 half-duplex mode. Serial data format:
Serial port settings: no/odd/even parity, 8-bit data, 1-bit stop bit.
Example: 9600,N,8,1 Meaning: 9600bps, no parity, 8 data bits, 1 stop bit.
The serial baud rate supported by this transmitter is:
2400,4800,9600,19200,38400,57600
The communication protocol can transmit signed plastic numbers and floating point data.
| Item | Condition | QJ726T-M-10 | QJ726T-M-30 | QJ726T-M-60 | QJ726T-M-90 | ||
| Test Range | ±10° | ±30° | ±60° | ±90° | |||
| Test Axis | X,Y | X,Y | X,Y | X,Y | |||
| Absolute Precision | ’-40~+85°C | 0.01 | 0.01 | 0.02 | 0.02 | ||
| Resolution | 0.001° | 0.001° | 0.001° | 0.001° | |||
| Long term stability | @25°C | <0.012 | <0.012 | <0.012 | <0.012 | ||
| Test Frequency | 100HZ | 100HZ | 100HZ | 100HZ | |||
| Zero Temperature Coefficient | ’-40~+85°C | ±0.008 | ±0.008 | ±0.008 | ±0.008 | ||
| Power-on start-up time | 0.2s | 0.2s | 0.2s | 0.2s | |||
| Interface | RS232/ RS422 / TTL / RS485 ( MODBUS RTU) | ||||||
| impact resistance | >20000g,0.5ms,3 times/Axis | ||||||
| anti-vibration | 10grms、10~1000Hz | ||||||
| Insulation impedance | >= 100 MΩ | ||||||
| Average work time | >= 55000 hours | ||||||
| Waterproof Level | IP67 , IP68 | ||||||
| Cable | High Temp with Shield 4*0.2, Standard 1.5meters | ||||||
| Voltage | DC10~36V | ||||||
| Current | DC12V, 35mA | ||||||
| Work Temp | -40~+85°C | ||||||
| Weight | 180g | ||||||
| Electric Connection | |||||||
| Red | Black | Green | Yellow | ||||
| RS232 | VCC | GND | RXD | TXD | |||
| RS485 | VCC | GND | (B、D-) | (A、D+) | |||
| TTL | VCC | GND | RXD | TXD | |||
| Red | Black | Green | Yellow | White | Brown | ||
| RS422 | VCC | GND | RXD-(B-) | RXD+(A+) | TXD+(A+) | TXD-(B+) | |
| Read X, Y date | |||||||
| Send Command: 01 03 00 01 00 04 15 C9 | |||||||
| Address (1byte) | Function (1byte) | Addr H (1byte) | Addr L (1byte) | Num H (1byte) | Num L (1byte) | CRC16L (1byte) | CRC16H (1byte) |
| 0x01 | 0x03 | 0x00 | 0x01 | 0x00 | 0x04 | 0x15 | 0xC9 |
| Response Command | |||||||
| Address (1byte) | Function (1byte) | Byte Count (1byte) | X Angle (4byte) | Y angle (4byte) | CRC16L (1byte) | CRC16H (1byte) | |
| 0x01 | 0x03 | 0x08 | XXXX XXXX | XXXX XXXX | XX | XX | |