Marine SCT Chargers and SCS Rectifiers
Power supplies meet all specifications and rules of China Classification Society, comply with the basic standards of marine electric and specifications, pass Type Approval of China Classification Society, and with the of GB7061 — 98 for and Control gear assemblies in Ships, GB IT 14548 — 93 General Specification for Marine Semiconductor Convertors and Rules for Classification Of Sea-going Steel Ships.
Marine SCT Charger with CCS Approval , Solas , IMO standards .
SC switch-mode Charging power supplies applying high-frequency PWM pulse—duration modulation technology and mainly composed Of IGBT, field effect power lube and integrated P WM controller. The complete machine adopts intelligent The reliable operation of power supplies can be ensured even in the hottest cabin, Power supplies meet all specifications and rules of China Classification Society, comply with the basic standards of marine electric and specifications, pass Type Approval of China Classification Society, and with the of GB7061 — 98 for and Control gear assemblies in Ships, GB IT 14548 — 93 General Specification for Marine Semiconductor Convertors and Rules for Classification Of Sea-going Steel Ships.
Rules for the product models of Charger and Rectifiers
SCT-2460-222X
SC – Marine DC products
T- Series : T- Charger S- Rectifiers
24- Output DC Voltage : DC12V, DC24V DC48V,DC110V,DC220V
60-Output current : 2A, 5A ,10A,20A,30A,40A,60A,80A,100A,125A,160A,200A
222-
The 1stdigital represents input voltage grade: 1 – AC110V, 2- AC220V, 3- AC380V, 4-AC440V.
The 2nd digital represents the grade of input phase number: 2, Single phase, 3-three phase
The 3rd digital represents the shell protection grade: 0- IP20 , 2 – IP22
The 4th digital code represents product identification number , used in the factory , it does not serve as a reference for customs .
When ordering goods, customers are advised to refer to “Preparation of Product Models” of the provide detailed requirements as far as possible and avoid the inconvenience brought by poor communication and the impact on delivery cycle. Selection of product output p o The nominal output power Of products in the company is defined as rated output under the condition of meeting service environments and performance indicators. Customers can select the appropriate power level of products according to practical maximum power. Customers are advised to use products through proper derating (20% to 50%), Load characteristics The charging of charging power supplies is generally designed according to the charging characteristics of lead-acid batteries at normal temperature In the cause of a need to lead-acid batteries or other types of batteries general working conditions, are advised to communicate and confirm With the technical Staff Of the company and indicate use conditions in Contract. Switching power supply products are generally applicable to impedance In the case of a need to use them under capacitive or inductive load Condition, advised to and confirm with the Staff of the company indicate the use conditions Of loads in the Contract.
Shell protection grade
Regarding series marine power supply products, power supplies Of the same kind have several Shell forms and different protection grades, respectively applicable to different installation requirements under different environments and show a great difference in price. Customers are advised to select appropriate product protection grades according to use conditions,
Range of input voltage
“Range Of Voltage Input” indicated in the product manual refers to the range Of normal operating voltage under the condition Of ensuring all performance indicators of power supplies. The power module Will encounter unstable performance or be damaged if input voltage exceeds this range. This kind of phenomena should be avoided,
Output power and heat emission conditions
The output power of power supplies refers to output power in the case of meeting certain heat emission conditions. Maximum operating temperature to ambient (M shell und« of leaving heat space (Air inlet outlet have a space Of no less than 200mm) around power supplies and ensuring the performance indicators Of supplies. Forced ventilation should be applied to the installation environment when necessary.
In general, the ambient operating temperature of power supplies in the absence Of heat emission is 20 to 40 C lower than the normal maximum operating temperature of power supplies. which depends on season and output power of power supplies. When using products. customers are advised to adopt the method of corresponding derating according to output and heat emission conditions to prolong the service life of products,
Parallel connection Of power supplies
The output parallel connection of two or multiple power supplies can be adopted in the case of needing higher output. At present, DC supply products of be directly connected in parallel. It is necessary to try to ensure the equal output voltage of each power Supply in the process of parallel connection so as to ensure the equal output power Of each power supply. There Should be enough heat emission space between power supplies in the parallel connection of power supplies. Customers are advised to communicate and confirm with the technical staff of the company.
A list for the quick selection of SCT chargers
SCT-2420 , SCT-2430 , SCT-2440 , SCT-2460 , SCT-2480 . SCT-24100 . SCT-24200
Input rat ed voltage (+15%)
(220) single-phase 220Vac (230) three-phase 220Vac (330) three-phase 330Vac (430) three-phase 440Vac
A list for the Quick Selection of SCS Rectifiers
SCS-2420 , SCS-2430, SCS-2440, SCS-2460, SCS-2480, SCS-24100 , SCS-24200
Panel diagram
Description of working indication (green); The working indicator light is on when the power supply is working normally.
Description Of fault indication (red): The fault indicator light is on When the power supply has a fault or Starts. After the removal Of output fault or the completion Of startup, the fault light is off and the working indicator light is on. Directions Users must clearly see the model of the power supply and know the input voltage grade of the power supply before use, Users Should connect input and Output in Strict accordance with wiring instruction. Users should pay attention to the positive and negative polarities of the load and then switch on the power after connecting wires according to thc wiring diagram and checking, Please do not open the case switching on the power, There is high pressure inside the case_ Be careful.
The power supply is equipped with output overvoltage, overload, short circuit protection, overheat protection and output undervoltage alarm. Alarm signal is outputted when the power supply IS protected.
The power supply automatically restores to work normally after the removal Of output fault. Thc power supply adopts the method of air cooling. The fan is controlled by current in order to extend its service life. The greater the output current is, the faster the rotational speed of the fan will be.