General Emergency Alarm System

The general emergency alarm panel RM-1B, complied with the rules and regulations of CCS and SOLAS, is the main product in the alarm system.And it can also be connected to the PA system to make the alarming signal spread over the vessel. Designed with the large-scale IC and micro-processing technology, the panel can produce kinds of alarming signal.

PRODUCTS CATEGORIES
PRODUCT DESCRIPTION

General Emergency Alarm System

General

The general emergency alarm panel RM-1B, complied with the rules and regulations of CCS and SOLAS, is the main product in the alarm system.And it can also be connected to the PA system to make the alarming signal spread over the vessel. Designed with the large-scale IC and micro-processing technology, the panel can produce kinds of alarming signal. The typical signals include:

G/A signal: 7 short pulses followed by 1 long pulse output repeatedly and periodically

Manual Alarm signal: signal output by the switch on or off

Fire Alarm signal: continuous frequency adjustment signal

Inputs:

2 buttons ‘the general emergency alarm’,’manual alarm ’ have been installed in the panel. The following can also be connected to the panel:

Alarm button: mounted on the bridge wing, the fire room or other places.

Fire Alarm:2 min after the fire alarm, PA system will work

Emergency Paging: All the alarms can be interrupted by the main controller of PA for the emergency paging.

Alarm Remote Station(RM-1A): mounted on the lifeboat to give ship-abandoning signal and emergency paging (water-proof)

Outputs

Alarm bell: through the power box WYC-1, the bell can be connected which is controlled by the output relay. Larger current relay box is available.

P/A: to spread the alarming signal over the vessel

E/R alarm indicator column: to extend the signal to the E/R; N.O contact output

Whistle controller: to extend signals based on tones; N.O. contact output

Cut off all the entertainment power; N.O. contact output

Technical Data

Power Supply: DC24V (18V–36V)    200mA(bell current excluded)

All the inputs are uncharged open contacts with the capacity of AC250V / 1.5A or DC24V/1.5A

The capacity of outputs are AC250V / 1.5A or DC24V/1.5A and the contact can’t connect the ring bells directly.

General alarm1

General alarm2

General alarm3

General alarm4

General alarm5