GMDSS Equipment Maintenance & Upkeep Standard Operating Procedures (SOP)
- General Rules
- Certified Operation Only: Only crew members holding a valid GMDSS General Operator’s Certificate (GOC) are authorized to operate and test the equipment.
- Accurate Logging: All test results, anomalies, and maintenance actions must be recorded in the GMDSS Radio Log on the same day.
- Immediate Reporting: Any equipment failure, low battery status, or approaching expiration date must be reported immediately to the Master and the company technical superintendent.
- Periodic Maintenance and Testing Schedule
| Frequency | No. | Equipment / Item | Core Inspection Points | Responsible Officer | Inspection Result / Signature |
| Daily | 1 | Power Switch Supply | Check main and emergency power supply change-over functions. Ensure all alarm indicators work. | 2nd Officer / OOW | □ OK / ______ |
| 2 | Reserve Source of Energy | Record battery charging/discharging voltage and current. Ensure batteries are fully charged. | 2nd Officer / OOW | □ OK / ______ | |
| 3 | Printers & Paper | Check DSC and NAVTEX printers. Ensure sufficient paper supply and clear printouts. | 2nd Officer / OOW | □ OK / ______ | |
| Weekly | 4 | VHF DSC Internal Test | Run the VHF DSC internal self-test loop without transmitting a radio signal. | 2nd Officer / OOW | □ OK / ______ |
| 5 | MF/HF DSC Internal Test | Run the MF/HF DSC internal self-test loop without transmitting a radio signal. | 2nd Officer / OOW | □ OK / ______ | |
| 6 | VHF DSC Test Call | Initiate a live DSC test call to a coast station or another vessel on the designated test frequency. | 2nd Officer / OOW | □ OK / ______ | |
| Monthly | 7 | EPIRB | Inspect for physical damage and watertight integrity. Check battery/HRU expiry dates. Run the non-transmitting self-test. | 2nd Officer / OOW | □ OK / ______ |
| 8 | SART | Check casing for cracks and battery expiry. Conduct a short-duration test using the ship’s X-band radar. | 2nd Officer / OOW | □ OK / ______ | |
| 9 | Two-way VHF Radios | Inspect battery condition. Conduct a voice test call using a dedicated test channel (NOT Ch.16). | 2nd Officer / OOW | □ OK / ______ | |
| 10 | Inmarsat-C Station | Execute a Performance Verification Test (PVT / Link Test) to verify proper satellite connection. | 2nd Officer / OOW | □ OK / ______ | |
| 11 | Antennas & Insulators | Wash off salt/dust from outdoor antennas. Check rigging tension and test antenna insulation resistance. | 2nd Officer / ETO | □ OK / ______ | |
| 12 | Battery Room | Check battery terminals for looseness or corrosion. Clean and apply petroleum jelly. Verify proper ventilation. | ETO / Engineer | □ OK / ______ |
- Critical Safety Consumables Expiry Control Log (Verify Monthly)
Use this table as a visual dashboard to prevent Port State Control (PSC) detentions due to expired safety components.
| Equipment Name | Item to Check | Manufacture / Last Replacement Date | Expiration Date | Status (OK / Order Required) |
| EPIRB | Lithium Battery | |||
| EPIRB | Hydrostatic Release Unit (HRU) | |||
| SART | Lithium Battery | |||
| Two-way VHF | Emergency Primary Battery (Must remain sealed) |
- False Distress Alert Prevention Protocol
- Strictly Prohibited: Never press any red “DISTRESS” button unless a real, imminent grave danger exists.
- Do Not Power Off: If a false DSC or satellite distress alert is transmitted accidentally, NEVER turn off the equipment.
- Immediate Cancellation: Broadcast an immediate cancellation message on the same frequency/channel using the standard format, and contact the nearest Coast Radio Station (CRS) or Rescue Coordination Center (RCC).