Understanding Safety and Explosion-Proof Ratings for Marine Two-Way Radios

Understanding Safety and Explosion-Proof Ratings for Marine Two-Way Radios

 

When selecting a two-way radio for marine, offshore, oil & gas, or chemical applications, one of the most important questions is:

“Is the radio safe for use in hazardous areas?”

This question is different from simply asking whether a radio is waterproof or rugged.

A radio may have an IP67 or IP68 rating and still not be suitable for use in an explosive atmosphere. For hazardous locations, the radio may require special intrinsically safe (IS) certification such as ATEX, IECEx, FM, UL, or CSA.

This article explains the major safety classifications and how they relate to marine two-way radio applications.

  1. IP Rating vs. Explosion-Proof Certification

The first thing to understand is that IP protection and explosion protection are two different concepts.

An IP rating describes protection against:

  • Dust
  • Water
  • Moisture
  • Temporary or continuous immersion

For example:

IP Rating Protection Typical Application
IP54 Dust and water splash protection Industrial areas
IP55 Dust and water jets Outdoor applications
IP57 Dust protection and temporary immersion Marine and port environments
IP67 Dust-tight and temporary immersion Marine/offshore applications
IP68 Dust-tight and extended immersion Harsh marine environments

However:

IP67 or IP68 does NOT mean that a radio is explosion-proof or intrinsically safe.

A normal IP67 radio should not automatically be used inside an oil tank, refinery, LNG facility, or other hazardous area.

  1. What Is an Intrinsically Safe Radio?

For hazardous environments, the important term is:

Intrinsically Safe (IS)

An intrinsically safe radio is designed so that its electrical and thermal energy remains below levels that could ignite a flammable gas, vapor, or dust under specified conditions.

These radios are commonly used in:

  • Oil tankers
  • Chemical tankers
  • LNG carriers
  • Offshore platforms
  • FPSOs
  • Refineries
  • Petrochemical plants
  • Oil terminals
  • Fuel storage facilities

A typical certified radio may carry markings such as:

Ex ib IIC T4 Gb

The individual parts of this marking provide important information about where the radio can be safely used.

  1. ATEX and IECEx

Two important international explosion-protection certification systems are ATEX and IECEx.

ATEX

ATEX is widely used in the European market and covers equipment intended for potentially explosive atmospheres.

A radio might have a marking such as:

II 2G Ex ib IIC T4 Gb

IECEx

IECEx is an international certification system based on IEC standards and is widely encountered in the marine, offshore and oil & gas industries.

For example:

Ex ib IIC T4 Gb

Both systems provide information about the equipment’s suitability for hazardous environments.

  1. Hazardous Area Zones

One of the most important concepts when selecting an intrinsically safe radio is the Zone classification.

Hazardous Area ATEX / IECEx Typical Situation
Zone 0 Zone 0 Flammable gas is present continuously or for long periods
Zone 1 Zone 1 Flammable gas is likely to occur during normal operation
Zone 2 Zone 2 Flammable gas is normally not present, but may occur temporarily

For example:

Zone 0

This represents a very high-risk environment.

Examples can include areas inside tanks or other locations where a flammable atmosphere may exist continuously.

Equipment intended for Zone 0 generally requires a higher level of intrinsic safety, commonly associated with Ex ia protection.

Zone 1

Zone 1 is commonly encountered around certain oil, gas and chemical processing areas.

A radio may require certification such as:

Ex ia / Ex ib

depending on the specific certification and application.

Zone 2

Zone 2 is a lower-risk hazardous area where flammable gas is not normally present but could occur under abnormal conditions.

Equipment with an appropriate Ex ic or other approved protection concept may be suitable, depending on the certification.

  1. Understanding Gas Groups: IIA, IIB and IIC

The explosion-protection marking also identifies the gas group.

Gas Group General Level Example
IIA Lower Propane
IIB Higher Ethylene
IIC Highest Hydrogen, Acetylene

In general:

IIC > IIB > IIA

A radio certified for IIC generally has a higher gas-group capability than one certified only for IIA or IIB.

Therefore, if a customer specifically requires:

IIC

you should not assume that an IIA or IIB radio is an acceptable substitute.

The exact certificate should always be checked.

  1. Temperature Classes: T1 to T6

Explosion-protected equipment is also classified according to its maximum surface temperature.

Temperature Class Maximum Surface Temperature
T1 ≤ 450°C
T2 ≤ 300°C
T3 ≤ 200°C
T4 ≤ 135°C
T5 ≤ 100°C
T6 ≤ 85°C

The lower the temperature, the more restrictive the requirement.

Therefore:

T6 is more restrictive than T4.

For example, a customer may specify:

Ex ib IIC T4 Gb

This tells you considerably more than simply knowing that the radio is “explosion-proof.”

  1. How to Read an Explosion-Proof Marking

Let’s take this example:

II 2G Ex ib IIC T4 Gb

It can be roughly interpreted as follows:

Marking Meaning
II Equipment group for non-mining applications
2G Equipment category for gas atmospheres
Ex Explosion-protection equipment
ib Intrinsic safety protection level
IIC Gas group
T4 Maximum surface temperature ≤135°C
Gb Equipment Protection Level for gas environments

The complete certificate, rather than the marking alone, should be used for final application approval.

  1. US Hazardous Area Classification

In the United States, hazardous locations are often classified using the Class/Division system.

For gas and vapor environments:

Class I

Class I refers to locations where flammable gases or vapors may be present.

The two common divisions are:

US Classification Meaning
Class I, Division 1 Hazardous atmosphere may exist during normal operation
Class I, Division 2 Hazardous atmosphere normally does not exist, but may occur under abnormal conditions

US applications may also use the Class I, Zone 0/1/2 system.

Common certification organizations include:

  • FM
  • UL
  • CSA

Therefore, a US customer may ask for a radio certified for:

Class I, Division 1

or:

Class I, Division 2

  1. Practical Selection Guide for Marine Radios

For marine equipment distributors and system integrators, the following simplified guide can be useful:

Application Typical Requirement
Normal vessel accommodation Standard radio
General outdoor marine use IP55/IP67
Wet deck / port operations IP67/IP68
Oil tanker IP67/IP68 + appropriate Ex certification
Chemical tanker IP67/IP68 + appropriate Ex certification
LNG carrier Appropriate Ex certification
Offshore platform Appropriate ATEX/IECEx or US certification
Zone 0 High-level intrinsic safety, typically Ex ia
Zone 1 Appropriate Ex ia / Ex ib equipment
Zone 2 Appropriate Ex equipment, depending on certificate
US oil & gas FM/UL/CSA, Class I Div 1/Div 2 or Zone certification

This table is a selection guide rather than a direct certification equivalency table. The actual hazardous-area classification and equipment certificate must always be checked.

  1. Don’t Forget the Radio Accessories

There is another important issue that is sometimes overlooked.

If you are using an intrinsically safe radio, you cannot necessarily connect any ordinary:

  • Headset
  • Speaker microphone
  • PTT switch
  • Earpiece
  • Extension cable
  • Connector
  • Battery

The accessory may also need to be specifically approved for use with the intrinsically safe radio.

For example, if a customer wants a:

Marine headset + PTT for an ATEX/IECEx radio

you should check the radio manufacturer’s approved accessory list.

Using an ordinary headset or PTT may potentially invalidate the approved configuration of the intrinsically safe equipment.

This is particularly important when modifying a conventional four-wire headset into a two-way radio headset with PTT.

  1. Key Takeaways

When selecting a marine two-way radio, don’t look only at the IP rating.

You should check four major areas:

  1. IP Rating
    Is the radio protected against water and dust?
  2. Hazardous Area Zone
    Is it intended for Zone 0, Zone 1, Zone 2, or a non-hazardous area?
  3. Explosion-Proof Certification
    Does it have the required ATEX, IECEx, FM, UL, CSA or other certification?
  4. Gas and Temperature Classification
    Does the certification meet the required gas group and temperature class, such as:

IIC / T4

For a professional marine or offshore installation, the safest approach is to start with the customer’s required hazardous-area classification and then select a radio whose complete certification matches that requirement.

IP67 means waterproof protection.
Intrinsically Safe means protection against ignition hazards.
They are not the same thing.

 

About IMARINEX

Imarinex One-stop ship communication and navigation supplier, originating from China, serving the world.

Share This Page
Get A Free Quote
Contact Form Demo (#3)
Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
Scan the code